Description
KR-SK800 automatic closed cup and open cup flash ignition point tester is manufactured according to GB/T261-2008 "Pensky-Martin closed cup method for flash point determination", ASTM D93 standard, GB267 "Petroleum product flash point and ignition point measurement method (open cup method) and GB3536 "Petroleum product flash point and ignition point measurement method (Cleveland open cup method)" standard method. It is an ideal instrument for performing flash point testing (closed cup and open cup) in petroleum, chemical, electric power, environmental protection, railway, scientific research and other fields.
Main Features:
1. Adopt high-speed signal processor control, adaptive PID control algorithm, and automatically adjust the heating curve according to standard requirements.
2. Built-in atmospheric pressure automatic detection chip, automatic measurement of atmospheric pressure, automatic correction of flash point value.
3. Data storage function, can store 300 results, and check the history at any time.
4. Differential detection, automatically correct system deviation and stop detecting and alarming when the temperature exceeds the value.
5. The instrument automatically completes lifting, stirring, ignition, detection, alarm, cooling, and printing.
6. Safe airless source, platinum alloy electric heating wire ignition mode, safe, stable, reliable, high test accuracy.
7. Optional Chinese and English operation interface, instrument program can be upgraded when national standards are revised.
Main Technical Parameters:
Display 10 inch 65K(resolution 800*600) Chinese and English touch screen
Measurement method Thermocouple differential detection
Measuring range Open cup: room temperature to 400 ° C, closed cup: room temperature to 350 ° C
Repeatability Closed cup: National standard: tolerance value ±1 °C when flash point value 110 °C.
Open Cup: ±2℃
Resolution 0.1 °C
Printer High speed thermal printer, 56 mm paper width
Ignition method Airless source electronic ignition
Temperature detection imported precision platinum resistance
Cooling method forced air cooling
Self-test function automatic diagnosis of instrument failure
Power consumption <550W
Operating environment Temperature 10 ° C -45 ° C, humidity 30-80%
Dimensions 450*280*290mm
Power source AC220V±10%
Weight about 15 kg
104>
- flash point tester
- flash point analyzer
- fire point tester
- closed cup flash point analyzer
- open cup flash point tester
Production Capacity:
300
Delivery Timeframe:
Immediate
Incoterms:
CFR - Cost and Freight
CIF - Cost, Insurance and Freight
CIP - Carriage and Insurance Paid to
EXW - Ex Works
FOB - Free on Board
Packaging Details:
Not informed
More about
Chongqing Kolery Trading Co., Ltd
10-50
Employees
500K - 1M
Sales volume (USD)
90%
% Export sales
Year
Established
Business type
- Industry / Manufacturer
- Importer / Trading Company
Keywords
- petroleum testing
- laboratory instruments
- karl fischer titrator
- flash point tester
- octane meter
- viscosity meter
- density meter
- pour point meter
- analytical balance
- ph meter Ver Mais
Contact and location
- Julie Wang
- +86 23 xxxxxxxx
- chongqing / | China