Description
First, the advantages of floor-standing aerosol S-type aerosol:
Easy to store: S-type aerosol extinguishing agent will not leak, no pressure vessel is required, no pipe network is required, and can be quickly discharged after release.
Green environmental protection: good cleanliness, non-toxic, non-corrosive, non-conductive, does not destroy the atmospheric ozone layer.
It is an excellent green environmental protection product.
Economical and durable: Aerosol fire extinguishing systems occupy a small footprint, low cost, easy to set up, wide adaptability, easy maintenance, long service life and other advantages are ideal alternatives to other types of fire extinguishing products.
Fast and efficient: In terms of fire extinguishing efficiency, the fire extinguishing efficiency of S-type aerosol is about 17 times that of carbon dioxide, 13 times that of mixed inert gas, 9 times that of heptafluoropropane, and 4 times that of Hailong, and the fire extinguishing efficiency is much higher than that of other fire extinguishing systems.
SECOND, the scope of application:
The S-type aerosol automatic fire extinguishing system is a fully submerged fire extinguishing system, which is suitable for extinguishing class A, B, C and E fires in relatively enclosed spaces.
Construction industry: high-rise buildings, substations of industrial buildings, libraries, archives, reference rooms, underground storage rooms, safes.
Communication industry: telecommunications machine room, computer room, communication base station, relay station, distribution cabinet data processing room, remote control room, precision equipment distribution cabinet.
Power industry: cable tunnels, cable wells, cable trenches in narrow spaces, generator rooms, substations, UPS systems, various power plant equipment.
Metallurgical industry: rolling mill equipment room, electronic instrument control room, electrical basement, cable sandwich, cable tunnel transformer room.
Petrochemical industry: flammable liquid storage area, insulated oil depot, transformer (distribution) room, generator room, cable tunnel, cable well, distribution cabinet, switch cabinet.
Transportation industry: train locomotives, railway source line signal stations, substation station signal buildings, highway signal stations, car engine rooms, turbine rooms, ship engine rooms.
Other industries: CNC and other high-priced machines, high-priced mobile devices.
Three. Main technical parameters:
1. Working environment temperature: 120 °C ~ +55 °C
2. Working environment relative humidity: ≤95%
3. Working storage pressure: atmospheric pressure
4. Design density: 130g/M3
5. Starting voltage: DC 3~24V/AC3~220V
6. Start current/time: 1 A/5ms
7. Maximum safety current and time: ≤150mA/5min
8. Minimum starting current and time: ≧250mA/5ms
9. Service life: 7 years
10. The system is convenient and can be connected to multiple units
- Floor-standing aerosols
- aerosol fire extinguishing systems
- aerosol fire extinguishing products
Production Capacity:
1000000
Delivery Timeframe:
Within 60 Days
Incoterms:
FOB - Free on Board
Packaging Details:
泡沫和玻璃袋包装,然后装棕色五层纸箱,最后装免熏蒸木箱,他们一起再装到集装箱里。
More about
Jiangxi Aware Fire Technology Co.,Ltd
200-500
Employees
50M - 100M
Sales volume (USD)
50%
% Export sales
Year
Established
Business type
- Industry / Manufacturer
Keywords
- gas fire suppression system
- aerosol fire extinguisher
- fire alarm system
Contact and location
- sam wong
- +86 xxxxxxxx
- xinyu / jiangxi | China